Catalytic Combustion Hydrogen Sensor SRE1012

Catalytic Combustion Hydrogen Sensor SRE1012
Details:
Fast response and recovery
Strong anti-interference ability
High precision
Send Inquiry
Download
Description
Technical Parameters
Product Introduction

 

  The SRE1012 hydrogen sensor is a catalytic combustion gas sensor developed based on nanotechnology. The sensor has good stability, reliability and test accuracy, and can be used to detect hydrogen gas concentration in different scenarios.

 

  In addition to sensors, our company also provides complete detection modules which include test circuits and algorithms for direct use.

 

Main Applications

 

● Hydrogen alarm instrument

● Hydrogen concentration test analysis

● Hydrogen leak detection for hydrogen powered vehicles

● Hydrogen leak detection at hydrogen fueling station

 

Sensor Characteristics

 

● Low temperature drift ( <1.5mV )

● Wide measuring range

● Fast response and recovery

● High precision

● Strong anti-interference ability

● Anti -poisoning by HMDS, H2S , SO2 , etc.

● High stability and reliability

 

For more information, Please check our product datasheet or send the consultation to us.

 

 

Hot Tags: Catalytic Combustion Hydrogen Sensor SRE1012, China Catalytic Combustion Hydrogen Sensor SRE1012 manufacturers, suppliers, factory, Volatile Organic Compounds Gas Sensor, Battery Safety Gas Detection Module, force sensor flex, Freon Semiconductor Sensor, portable gas detector, portable gas detector for confined space

Technical specifications

Environmental parameters

Temperature Range

Work:

-40 ~ 85℃

Storage:

-40 ~ 125℃

Humidity Range

Work:

0 ~ 95%

Storage:

0 ~ 100%

Pressure Range

70 ~ 130kPa

Test Gas

H2

 

Sensor Characteristics

Working Voltage

0.8V

Working Current

150 ~ 180mA

Sensitivity (1%H2@0.8V)

> 25mV

Baseline Temperature Drift

< 1.5mV

Annual Drift

< 2mV

Linearity

> 99%

H2 test Range

0 ~ 4%

Response Time (T80)

< 3 sec

Recovery Time (T10)

< 3 sec

Repeatability

< 0.5mV

 

Selectivity

Gas

Concentration (ppm)

Response value (mV)

CO

50

< 0.5

NO2

5

< 0.5

H2S

20

< 0.5

CH4

10000

< 3

NH3

50

< 0.5

CO2

5000

< 0.5

SO2

500

< 0.5

 

Send Inquiry