Product Introduction
The SMD1007 hydrogen sulfide gas sensor is a MEMS micro gas sensor developed based on specific semiconductor gas-sensitive materials. It can be used to detect the hydrogen sulfide gas content in different scenarios.
The hydrogen sulfide gas sensitive material developed and made by IDM independently. When H2S gas contacts the sensitive material, the conductivity of the sensitive material will change. A specific test circuit can be used to convert the this change into an output voltage signal corresponding to the gas concentration.
Main Applications
It is widely used in the testing of hydrogen sulfide gas in scenarios such as
● Food testing
● Public sanitation
● Livestock
● Portable detectors
Sensor Characteristics
● Small size
● Low power consumption
● High sensitivity
● Fast response and recovery time
● Simple test circuit
● Good stability
● Long life time
Sensor Package
Packing quantity: 1 reel = 5000pcs
Packing weight: 1 reel : around 920g

For more information, Please check our product datasheet or send the consultation to us.
Hot Tags: MEMS Hydrogen Sulfide Gas Sensor SMD1007, China MEMS Hydrogen Sulfide Gas Sensor SMD1007 manufacturers, suppliers, factory, MEMS H2 Sensor, electronic nose gas sensor, ozone sensor module, LNG Sensor, TVOC Gas Sensor Module, portable gas detector instructions
|
Product Number |
SMD1007 |
|||
|
Product Type |
MEMS Semiconductor Sensors |
|||
|
Standard Package |
Ceramic Package |
|||
|
Target Gas |
Hydrogen Sulfide H2S |
|||
|
Measurement Range |
0 ~ 3 ppm (hydrogen sulfide) |
|||
|
Resolution |
0.01 ppm |
|||
|
Standard Circuit Conditions |
Sensor Voltage |
V C |
5 V or 3.3 V DC |
|
|
Heating Voltage |
V H |
1.8 V ± 0.05 V DC |
||
|
Load Resistance |
R |
Adjustable (subject to shipping sheet) |
||
|
Gas Sensor Characteristics Under Standard Test Conditions |
Heater Resistance |
R H |
43 ± 5 Ω ( measured at room temperature ) |
|
|
Heating Power Consumption |
P H |
≤ 36 mW |
||
|
Sensor Resistance |
R S |
10 ~ 100 KΩ ( tested in air ) |
||
|
Sensitivity |
S |
R 0 (in air) / Rs (in 0. 2 ppm H2S )≥1.8 |
||
|
Response Ratio |
α |
≤ 0.5 (R 1 pp m / R 0.2 pp m Hydrogen sulfide) |
||
|
Standard Test Conditions |
Temperature Humidity |
20±2 ℃ 55±5 %RH |
||
|
Preheat Time |
3-5 min |
|||
|
Response Time ( T90 ) |
< 3 0 s |
|||
|
Recovery Time (T10 ) |
< 6 0 s |
|||
|
Life Time |
≥ 3 years |
|||