Infrared CO2 Gas Sensor Module 5000PPM MWD1006-5000

Infrared CO2 Gas Sensor Module 5000PPM MWD1006-5000
Details:
Wide temperature compensation range
Ultra-low power consumption
Anti-interference from moisture
Send Inquiry
Download
Description
Technical Parameters
Product Introduction

 

  The MWD1006 is a gas detection module based on the NDIR infrared absorption technology. It uses a single light source and a single-channel detector. The sampling method use self-diffusing. MWD1006 is suitable for detecting the concentration of carbon dioxide in indoor and outdoor air. MWD1006 has digital UART and PWM waveform output methods, which is convenient for application. MWD1006 has automatic zero point calibration, sensitivity calibration and clean air calibration functions. It also provides a manual calibration MCDL pin, which is for customers to use outdoor clean air to perform relative zero point calibration on the sensor module.

 

Main Application

 

  MWD1006 can be widely used in air conditioning and fresh air control, indoor air quality monitoring, agricultural and animal husbandry production process monitoring. It can be installed in intelligent buildings, ventilation systems, controllers, wall-mounted applications, robots, automobiles and other applications. It can also be used in small space air quality monitoring.

 

Module Characteristics

 

● Ultra-low power consumption

● Optional output interfaces: UART, PWM

● Wide temperature compensation range

● Anti-interference from moisture

 

 

For more information, Please check our product datasheet or send the consultation to us.

 

 

Hot Tags: Infrared CO2 Gas Sensor Module 5000PPM MWD1006-5000, China Infrared CO2 Gas Sensor Module 5000PPM MWD1006-5000 manufacturers, suppliers, factory, alcohol sensor, Industrial Alarm Monitor, MEMS Ammonia Sensor, Alcohol Gas Sensor, MEMS TVOC Gas Sensor, Carbon Monoxide Detection Module

Product Specifications

 

1 Working conditions

 

Item

Symbol

Value

Unit

Storage temperature

Tstg

-20 to 80

°C

Working temperature

TA

-10 to +50

°C

Working humidity

HA

0 to 90

%RH

Working pressure

PA

0.8 to 1.2

atm

 

2 Electrical characteristics

 

Item

Symbol

Minimum

Typical

Maximum

Unit

Power supply

Vs

4.5

5

5.5

V

Maximum current

Imax

 

120

150

mA

Average current

Iave

30

36

90

mA

 

3 Technical indicators

 

Item

Min

Typical

Max

Unit

Range *

 

5000

 

ppm

Measurement accuracy

±50ppm or ±5% of true value, whichever is greater

ppm

Resolution

25

ppm

Response time (T90)

Diffusion

-

120

-

Second

Repeatability

50% FS

-

<±5% of measured value

-

 

Life time

3

5

10

Year

Remark: * Range can be customized

 

4 Module size

product-539-242

product-524-363

Note: Unit: mm, Tolerance: Pin pitch ±0.1mm, Other tolerances: ±0.2mm