Semiconductor Methane Gas Sensor Module MMD1008T

Semiconductor Methane Gas Sensor Module MMD1008T
Details:
Low power consumption
Simple application circuit
Long life time
Send Inquiry
Download
Description
Technical Parameters
Product Introduction

 

  The The MMD1008T gas sensor module uses a metal oxide semiconductor sensor. When a trace amount of alkane gas reach sensor surface, the conductivity of the sensing material will increase. The change in conductivity related with gas concentration. Through the magnitude of the change in conductivity, the sensor can sense the degree of gas leakage in the air. For example, when indoor leaking gas molecules contact the sensor, the sensor can produce a conductivity change. Using this sensitive characteristic of the sensor, and then through a simple single-chip microcomputer and firmware control, the alarm device can be intelligently started, and the exhaust ventilation equipment can be started at the same time.

 

Main Application

 

Safety monitoring for those vehicle using natural gas as power

Indoor flammable gas leakage detection

Ventilation control system

Industrial methane, natural gas detection

Portable gas leak tester

Household gas alarm and automatic alarm control system, etc

 

Sensor Module Characteristics

 

Low power consumption

long life time

Low cost

Small size

Simple application circuit

High sensitivity to alkane gases

 

For more information, Please check our product datasheet or send the consultation to us.

 

 

Hot Tags: Semiconductor Methane Gas Sensor Module MMD1008T, China Semiconductor Methane Gas Sensor Module MMD1008T manufacturers, suppliers, factory, Resistive Flexible Film Pressure Sensor, Alcohol Detection Sensor, MEMS C3H8 Sensor, CO Detection Module, lel gas sensor, Industrial Alarm Monitor

Product Number

MMD1008T

Sensor Model

SMT-014

Target Gas

Natural gas, liquidfied petrolem gas(LPG), Butane gas and other alkane gases

Data Communication

Interface Connector

XH2.54-4 Vertical terminals

Output Data

TTL High/Low level/UART (5V level)

Input Voltage

5.0±0.2VDC (no polarity protection)

`Module Operation Condition

Working Current

≤ 100 mA

Response Time

≤20 seconds

Preheat Time

120 seconds

R2 load resistor

10 -100KΩ

Measurement Range

0-10000ppm methane

Test Environmental Parameter

Working Temperature

0-50℃

Storage Temperature

-20℃- 60℃

Working Humidity

≤95%RH

Storage Humidity

≤ 60%RH

Appearance Parameter

Module weight

About 20g

Dimension

24×20×15mm (L×W×H)